{"product_id":"kartridzh-3-h-hodovogo-klapana-dlya-gazovogo-kotla-tiberis-cube-24-f-306221113","title":"Tiberis Gas Boiler 3-Way Valve Cartridge Cube 24 F (306221113)","description":"\u003ch2\u003e3-Way Valve Cartridge (Repair Kit) for Tiberis Cube 24 F Gas Boilers (Part Number: 306221113)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe original three-way valve cartridge (core\/stem) (part number 306221113)\u003c\/strong\u003e is designed to switch the coolant flow between the heating circuit and the secondary plate heat exchanger for DHW (domestic hot water) in dual-circuit gas boilers. The part is subject to natural wear and tear due to scale and hard water salts; therefore, replacing the cartridge allows for the full restoration of the hydraulic group's functionality without purchasing an expensive complete brass assembly.\u003c\/p\u003e\n\n\u003ch3\u003eSymptoms of a Faulty Three-Way Valve Cartridge:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eWhen hot water (DHW) is turned on, the boiler continues to heat the radiators, and the water from the tap is cool or lukewarm.\u003c\/li\u003e\n    \u003cli\u003eIn heating mode, hot water mixes into the DHW circuit or vice versa.\u003c\/li\u003e\n    \u003cli\u003eCoolant leakage through the stem oil seal under the three-way valve actuator (servo motor).\u003c\/li\u003e\n    \u003cli\u003eStem jamming due to scale deposits or damage to internal rubber seals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Advantages:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDurable brass stem:\u003c\/strong\u003e Highly resistant to corrosion, mechanical wear, and high coolant temperatures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-quality NBR seals:\u003c\/strong\u003e Ensure 100% tightness in separating the heating and hot water circuits.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCost savings:\u003c\/strong\u003e Allows for quick repair of the boiler's hydraulic block without replacing the entire assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility and Application:\u003c\/h3\u003e\n\u003cp\u003eUsed in dual-circuit wall-mounted gas boilers of the \u003cstrong\u003eTiberis\u003c\/strong\u003e brand, as well as analogs with a similar hydraulic group:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTiberis gas boilers:\u003c\/strong\u003e Tiberis Cube 24 F, Tiberis Cube 18 F, Tiberis Cube 24 C, Tiberis Oberon 18\/24\/28 C\/F.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRelated brands:\u003c\/strong\u003e Compatible with Hermann, Italtherm, Fondital, Nova Florida, and other models using standard 306221113 cartridges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n            \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eValue \/ Specification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePart type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCartridge \/ repair kit \/ three-way valve core\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePart Number (P\/N)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e306221113\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePurpose\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSwitching water flow between heating and DHW circuits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStem\/body material\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBrass \/ heat-resistant composite\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eActuator type (control)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFor electric servo actuator (three-way motor)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePackage Contents:\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e3-way valve cartridge 306221113 — 1 pc.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cem\u003eTechnician's tip: Before replacing the cartridge, be sure to close the water supply valves, drain the coolant from the boiler, and thoroughly clean the internal brass chamber of the three-way valve from scale and sludge deposits. When installing the new repair kit, apply a thin layer of silicone plumbing grease to the rubber seals.\u003c\/em\u003e\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":43546600800433,"sku":"00000051628","price":2178.51,"currency_code":"UAH","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0538\/8517\/3937\/products\/00000051628.jpg?v=1710894391","url":"https:\/\/usefulrare.com\/products\/tiberis-gas-boiler-3-way-valve-cartridge-cube-24-f-306221113","provider":"Dostavka","version":"1.0","type":"link"}